Copper (Aluminum) -cored power cable in PVC insulation & PVC (PE) sheath
Standards:
The cable is manufactured according to GB12706-2002 national standard or international electrical committee standard of IEC502-1994
Type:
VV---Copper-cored power cable in PVC insulation & PVC sheath
VLV---Aluminum -cored power cable in PVC insulation & PVC sheath
VY---cored power cable in PVC insulation & PE sheath
VLY---Aluminum-cored power cable in PVC insulation & PE sheath
Use:
The cables can be fixedly laid in the environments such as indoor, aerial, cable conduit and tunnel for power transmission and distribution line project in rated A/C UO/U at 0.6/1KV and below.
Copper (Aluminum) -cored power cable with PVC insulated (armored) & PVC (PE) sheathed
Standards:
The cable is manufactured according to GB12706-2002 national standard or international electrical committee standard of IEC502-1994
Type:
VV22---Copper-cored
power cable with armored in PVC insulation & PVC sheath
VLY22---Aluminum-cored power
cable witharmored in PVC insulation & PVC sheath
VV23---Copper-cored power cable
with armored in PVC insulation & PE sheath
VLY23---Aluminum-cored power
cable with armored in PVC insulation & PE sheath
Use:
The cables can be fixedly laid in the places where cables can be protected from much strong extraneous mechanical force to a certain degree, such as indoor, aerial, cable conduit tunnel or direct burying for power transmission and distribution line project in rated A/C UO/U at 0.6/1KV and below.
Copper-cored control cable with PVC insulated (armored) & sheathed
Standards:
The cable is manufactured according to GB9330-88 national standard or international electrical committee standard of IEC227--1979
Type:
KVV---Copper-cored control power cable in PVC insulation & PVC sheath upon GB9330-88 of Chinese standard
KVV22---Copper-cored control power cable with armored in PVC insulation & PVC sheath upon GB9330-88 of Chinese standard
KVVP2---Copper-cored control power cable with copper belt shielded in PVC insulation & PVC sheath upon GB9330-88 of Chinese standard
KVVP---Copper-cored control cable with intertexture shielded in PVC Insulation & PVC sheath upon GB9330-88 of Chinese standard
Use:
The cables can be applied to control single machine or sets of machine devices in the places of generating power station ,varying power station ,mine, and petrochemical enterprise, etc in the rated A/C voltage at 450/750 and below.
The cable is manufactured according to GB5023-1997 and JB8734-1998 national standard or international standard of 227IEC
Type:
227 IEC01(BV)---Copper-cored electric wire in PVC insulation
BLV---450/750V---Aluminum-cored electric wire in PVC insulation
BVR---450/750V---Copper-cored soft electric wire in PVC insulation
227 IEC10BVV---Copper-cored round electric wre with
PVC insulated & sheathed
BLVV 300/500V JBB8734.2-1998---Aluminum-cored round power cable in PVC insulation & PVC sheath
BVVB---300/500V JBB8734.2-1998---Copper-cored parallel power cable in PVC insulated & PVC sheath
BLVVB---300/500V JBB8734.2-1998---Aluminum-cored flat power cable in PVC insulation & PVC sheath
Use:
The cables can be applied to the copper(aluminum)-core cables in the rated A/C voltageof U450/750V and below for power, lighting, daily electric appliances, apparatus & meter and telecommunication equipments
Copper-cored fire-resistant electrical wire cable with PVC (armored) & sheathed
Standards:
Q/GL120001
Type:
NH-BV-450/750V---Copper-cored fire resistant electric wire in PVC insulation
NH-BVVB 300/500V---Copper-cored fire resistant flat power cable in PVC insulation & PVC sheath
NH-VV---Copper-cored fire resistant power cable in PVC insulation & PVC sheath
NH-VV22-Copper-cored fire resistant power cable with armored in PVC insulation & PVC sheath
NH-KVV-Copper-cored fire resistant control power cable in PVC insulation & PVC sheath
NH-KVV22-Copper-cored fire resistant control power cable with armored in PVC insulation & PVC sheath
Use:
The products can be used for PVC insulated & fire-resistant cable in A/C rated voltage at 0.6/1kv and below. When it was placed in the firing situation at the fire disaster frequent area, it can still keep working for some time at the fixed laying situation .
Q/GL120000.The cable is manufactured according to GA306.1-2001 and international electric committee standard of IEC502, IEC322-3(1992)
Type:
ZR-227IEC01(BV)---Copper-cored flame retarding electrical wire in PVC insulation upon
international electric committee standard 227IEC
ZR-BLV---Aluminum-cored flame retarding electrical wire in PVC insulation
ZR-BVV---Copper-cored flame-retarding power cable in PVC insulation & PVC sheath
ZR-BLVV---Aluminum-cored flame-retarding power cable in PVC insulation & PVC sheath
ZR-227IEC10(BVV)---Copper-cored flame-retarding power cable in PVC insulation & PVC sheath upon
international electric committee standard 227IEC.
ZR-VV---Copper-cored flame-retarding power cable in PVC insulation & PVC sheath
ZR-VLV---Aluminum-cored flame-retarding power cable in PVC insulation & PVC sheath
ZR-VV22---Copper-cored flame-retarding power cable with armored in PVC insulation & PVC sheath
ZR-VLV22---Aluminum-cored flame-retarding power cable with armored in PVC insulation & PVC sheath
ZR-KVV---Copper-cored flame-retarding control power cable in PVC insulation & PVC sheath
ZR-KVV2---Copper-cored flame-retarding control power cable with armored in PVC insulation & PVC sheath
Use:
The products can be applied to the power and control electric cable in bind of several roots with PVC insulated & flame retarding in A/C rated voltage at 0.6/1kv and below laying in the air .
Copper (Aluminum)-cored power cable with PE insulated & sheathed
Standards:
The cable is manufactured according to GB12706-2002 national standard or international electrical committee standard of IEC502-1994.
Type:
YJV---Copper-cored power cable in PE insulation & PVC sheath
YJLV---Aluminum-cored power cable in PE insulation & PVC sheath
YJY22---Copper-cored power cable with armored in PE insulation & PVC sheath
YJLV2---Aluminum-cored power cable with armored in PE insulation & PVC sheath
Use:
It is available to be installed in the indoor and power cable duct and tunnel in rated voltage of 0.6/1KV and below for power transmission